Abstract

Abstract Views: 435

A new study used potassium fluoride (KF) in different concentrations (2% and 5%), one of the components in the complete denture as supported material. The study aims to find the electrochemical analysis by cyclic voltammetric (CV) technique of the physical properties of this material and the influence in artificial saliva (AS) by oxidation–reduction peak current in the oral cavity. This study used a glassy carbon electrode (GCE) as a working electrode, Ag/AgCL as a reference electrode, and platinum wire as an auxiliary electrode in the cyclic voltammetry cell. Different physical properties such as concentration, pH, scan rate, and reproducibility study were used in the potential-state. The results showed  two oxidation peaks current at 1.4 and 0.75 Volt  characterize to the artificial saliva and KF respectively, and one reduction peak current at -0.5 Volt  for KF. All peaks were enhanced by increasing the concentrations and scan rates that indicate the study in the right response. Using different pH, the oxidation peak of KF disappeared in alkaline pH and enhanced in an acidic medium, so the KF ions act as an oxidative reagent in artificial saliva of acidic pH, and antioxidant in alkaline pH at a limited concentration of KF in the cavity of the mouth. The low concentration of KF (2%) used in the component of total denture is more favourable than the high concentration (5%). In addition, it is better to store the total denture in an alkaline solution after use to avoid any damage to the mouth cells.

Keywords:

Artificial Saliva, Cyclic Voltammetry, KF, pH, Redox

References

Adair, S. M., Whitford, G. M., & Hanes, C. M. (1994). In vitro effect of human saliva on the output of fluoride from controlled-release devices. Pediatric dentistry, 16(6), 410-412.

Baliga, S., Muglikar, S., & Kale, R. (2013). Salivary pH: A diagnostic biomarker. Journal of Indian Society of Periodontology, 17(4), 461–465. https://doi.org/10.4103%2F0972-124X.118317

Brett, C. M., & Muresan, I. (2002). The influence of artificial body fluids on metallic corrosion. Key Engineering Materials, 230, 459-462. https://doi.org/10.4028/www.scientific.net/KEM.230-232.459

Hellwig, E., Polydorou, O., Lussi, A., Kielbassa, A. M., & Altenburger, M. J. (2010). The influence of saliva on the dissolution of calcium fluoride after application of different fluoride gels in vitro. Quintessence international, 41(9). https://boris.unibe.ch/id/eprint/408

Huang, H. H. (2002). Effect of chemical composition on the corrosion behavior of Ni‐Cr‐Mo dental casting alloys. Journal of Biomedical Materials Research, 60(3), 458-465. https://doi.org/10.1002/jbm.10080

Ibrahim, A. I., & Radhi, M. M. (2021, March). Electrochemical study of Fe II/Fe III on modified GCE with PAN and PMMA at different temperatures using cyclic voltammetry. In Journal of Physics: Conference Series (Vol. 1853, No. 1, p. 012008). IOP Publishing. https://doi.org/10.1088/1742-6596/1853/1/012008

Opydo-Szymaczek, J., Pawlaczyk-Kamieńska, T., & Borysewicz-Lewicka, M. (2022). Fluoride Intake and Salivary Fluoride Retention after Using High-Fluoride Toothpaste Followed by Post-Brushing Water Rinsing and Conventional (1400–1450 ppm) Fluoride Toothpastes Used without Rinsing. International Journal of Environmental Research and Public Health, 19(20), 13235. https://doi.org/10.3390/ijerph192013235

Radhi, M. M., & Al-Mulla, E. A. J. (2015). Use of a grafted polymer electrode to study mercury ions by cyclic voltammetry. Research on Chemical Intermediates, 41(3), 1413-1420. https://doi.org/10.1007/s11164-013-1282-1

Radhi, M. M., Abdullah, H. N., Al-Asadi, S. A., & Al-Mulla, E. A. J. (2015). Electrochemical oxidation effect of ascorbic acid on mercury ions in blood sample using cyclic voltammetry. International Journal of Industrial Chemistry, 6(4), 311-316. https://doi.org/10.1007/s40090-015-0053-9

Radhi, M. M., Abdullah, H. N., Al-Asadi, S. A., & Al-Mulla, E. A. J. (2015). Electrochemical oxidation effect of ascorbic acid on mercury ions in blood sample using cyclic voltammetry. International Journal of Industrial Chemistry, 6(4), 311-316. https://doi.org/10.1007/s40090-015-0053-9

Radhi, M. M., Abdullah, H. N., Jabir, M. S., & Al-Mulla, E. A. J. (2017). Electrochemical effect of ascorbic acid on redox current peaks of CoCl 2 in blood medium. Nano Biomedicine and Engineering, 9(2), 103-106. https://doi.org/10.5101/nbe.v9i2.p103-106

Radhi, M. M., Abdullah, H. N., Jabir, M. S., & Al-Mulla, E. A. J. (2017). Electrochemical effect of ascorbic acid on redox current peaks of CoCl 2 in blood medium. Nano Biomedicine and Engineering, 9(2), 103-106.

Radhi, M. M., Alosfur, F. K. M., & Ridha, N. J. (2018). Voltammetric characterization of grafted polymer modified with ZnO nanoparticles on glassy carbon electrode. Russian journal of electrochemistry, 54, 27-32. https://doi.org/10.1134/S1023193518010068

Radhi, M. M., Ibrahim, A. I., Al-Haidarie, Y. K., Al-Asadi, S. A., & Al-Mulla, E. A. J. (2019). Rifampicin: Electrochemical effect on blood component by cyclic voltammetry using nano-sensor. Nano Biomedicine and Engineering, 11(2), 150-156. https://doi.org/10.5101/nbe.v11i2.p150-156

Wang, H. W., Bringans, C., Hickey, A. J., Windsor, J. A., Kilmartin, P. A., & Phillips, A. R. (2021). Cyclic voltammetry in biological samples: a systematic review of methods and techniques applicable to clinical settings. Signals, 2(1), 138-158. https://doi.org/10.3390/signals2010012

Electrochemical Behavior Study of KF in Artificial Saliva Mediated by GCE Using Cyclic Voltammetry

Published

2023-07-01

How to Cite

Abass, N. A. S., Rashid, A. A. L., & Radhi, M. M. (2023). Electrochemical Behaviour Study of KF in Artificial Saliva Mediated by GCE Using Cyclic Voltammetry. Biomedicine and Chemical Sciences, 2(3), 166–170. https://doi.org/10.48112/bcs.v2i3.474

Issue

Section

Articles